1. Skip to navigation
  2. Skip to content
  3. Skip to sidebar



Engineering Bulletins

Echelon's Engineering Bulletins provide architectural and design information on wide range of circuit, device, and system-related topics. Typical subjects include external memory and serial interfaces for Neuron Chips, power line system designs for demand side management applications, twisted pair wire specifications for the TP/FT-10 channel, mean time between failure analyses of Echelon products, and the standard method for implementing file transfers in LonWorks networks.

Audio | Custom Node Design | Gateways | Input/Output | LonWorks Protocol |
Media & Wiring | Power Line | Pyxos | Series 5000 | Miscellaneous

NOTE: Adobe Acrobat Reader is required to view all documentation. Download Acrobat Reader.

Audio

Document Title
Contents
Part Number
Determinism in Audio Computer Control Network Applications This paper deals with the importance of response time, and the unimportance of determinism, as elements in audio control networks.
LonWorks for Audio Computer Control Network Applications Describes how to use LonWorks technology to build intelligent audio products.

Custom Node Design

Document Title
Contents
Part Number
LonWorks Custom Node Development

Describes steps needed to design and test a LonWorks custom node. Includes hints and advice to help speed the process of designing these nodes. Also lists pitfalls to avoid.

Neuron 3150 Chip External Memory Interface
Describes interface and timing requirements for the memory bus of the Neuron 3150 Chip.

Gateways

Document Title
Contents
Part Number
Building a
LonTalk-to-PLC Gateway

Describes a general approach for building a gateway between a Programmable Logic Controller and a LonTalk network, with specific examples coming from a gateway implemented between a LonTalk network and an Omron PLC.

Input / Output

Document Title
Contents
Part Number
Analog-To-Digital Conversion With the Neuron Chip

Describes some of the more popular analog to digital (A/D) conversion schemes available for use with the Neuron Chip. Provides schematics, parts lists and code examples.

Driving a Seven Segment Display with the Neuron Chip

How the Neuron Chip can be used to drive a seven-segment display controller chip, the Motorola MC14489, using the Neurowire device. Includes Neuron C software drivers to display decimal numbers from binary data.

EIA-232C Serial Interfacing with the Neuron Chip


Describes a simple level conversion circuit to allow the Neuron Chip to communicate with RS-232C devices. Also includes Neuron C software to drive an RS232C CRT terminal.

Neuron Chip Quadrature Input Function Interface

 

Describes the use of the quadrature device in the Neuron Chip to interface to external devices such as shaft encoders.

Parallel I/O Interface to the Neuron Chip

Describes hardware and software to interface the Neuron Chip to a microprocessor using the parallel I/O port.

Scanning a Keypad with the Neuron Chip


Describes how the Neuron Chip can be used to scan a simple 16-key switch matrix to provide a numeric or special-function keyboard without the use of a keyboard encoder.

Using the Hardware Serial Peripheral Interface (SPI) and Neurowire I/O Object Models to Interface with
Peripherals and Microcontrollers
Describes communications between Smart Transceivers or Neuron Chips and other microcontrollers for designs that intend to make use of the SPI interface for simpler applications and also for understanding how the SPI interfaces are implemented in the Smart Transceivers and Neuron Chips. Neuron C code examples of an SPI interface are explained in this engineering bulletin, and the source code is available for download.

LonWorks Protocol

Document Title
Contents
Part Number
File Transfer

Describes the standard method of exchanging large amounts of data between nodes in a LonWorks network.

Media & Wiring

Document Title
Contents
Part Number
Junction Box and Wiring Guidelines for Twisted Pair LonWorks Networks

Identifies the different types of junction boxes and interconnections that can be used in twisted pair LonWorks networks in building and industrial control applications.

LonWorks 78Kbps Self-Healing Ring Architecture
Describes the benefits and limitations of two wiring methods for the TP-78 channel: bus and loop. The design of an intelligent switch for loop-wired systems is discussed.

Power Line

Document Title
Contents
Part Number
Centralized Commercial Building Applications with the PLT-21 Power Line Transceiver

The LonWorks PLT-21 power line technology in medium to large commercial installations using centralized architecture. The role of twisted pair backbones and network routers is discussed.

Data Logging with the PLCA-22 Power Line Communications Analyzer

The PLCA-22 Power Line Communications Analyzer provides a simple, cost-effective method of field testing the operation of Echelon's multi-frequency, CENELEC EN50065-1 and EIA 709.2 compliant, power mains communication technology.

Demand Side Management with LonWorks Power Line Transceivers

The use of LonWorks for residential DSM applications, an overview of DSM systems, a description of the transceiver, a review of wiring in a typical North America residence, and a detailed analysis of coupling circuits for a power line signal.

Pyxos

Document Title
Contents
Part Number
Pyxos™ FT Platform Interoperability

This bulletin explains network variable exchanges in a Pyxos FT network.

Series 5000

Document Title
Contents
Part Number
Connecting a Neuron® 5000 Processor to an External Transceiver This Engineering Bulletin describes how to connect a Neuron 5000 Processor’s communications port to external transceivers for TP/XF-1250 channels or for EIA-485 networks, using an external transceiver circuit. It also describes how to connect a Neuron 5000 Processor to a link-power TP/FT-10 channel using a LonWorks LPT-11 Link Power Transceiver.

Miscellaneous

Document Title
Contents
Part Number
Firmware Version Numbers for Neuron Chips and Smart Transceivers This document summarizes the firmware version numbers found in Neuron Processors and Smart Transceivers by vendor
Echelon FT 3120 and FT 3150 Free Topology Smart Transceiver Lightning Protection Technical Bulletin This documents outlines updates to certain specifications pertaining to lightning protection outlined in the FT 3120 / FT 3150 Smart Transceiver Data Book.

Design Practices for Using a LonWorks Free Topology Channel on Trains This bulletin discusses LonWorks TP/FT-10 free topology channel networks on trains and is a companion piece to Echelon's free topology user's guides and data books.

LonWorks Control Products Environmental Specifications and MTBF Guide Summarizes the environmental specifications of control products, mean time between failure (MTBF) statistics, and safety agency file numbers.

Understanding the Neuron® Firmware Address Table This bulletin describes the purpose of the address table, explains how this valuable resource is being used and explains how device manufacturers and integrators can control and optimize its use.
Usage Guidelines for Echelon Trademarks

This document outlines the proper use of Echelon's trademarks in printed and electronic media.
Contact Echelon directly for questions and permission about the use of Echelon's logos.

Error processing SSI file